Preview

Dependability

Advanced search

Measures to improve the dependability of automated power grid process control equipment

https://doi.org/10.21683/1729-2646-2017-17-1-11-16

Abstract

Automated control equipment is being progressively integrated into the power grid. Automated process control in the electric power industry involves the ability to control the position of electrical switching devices, monitor their current status, as well as display numeric data on currents, voltages, etc. Disruptions in the automated operations control facilities (AOCF) cause defects in power systems and grid equipment. AOCF failures impair condition monitoring of power grids and operation of switching devices. Due to the impossibility of real-time remote management of power supply installations, the power provider is unable to guarantee continuous power supply. The article analyzes the AOCF equipment currently in operation as part of distributed systems at power substations, looks into the advantages and drawbacks of specific facilities, suggests methods to increase the dependability of equipment operation in the context of a 35-110 kV distributed power supply network. An AOCF equipment certification procedure is proposed. It is also suggested to provide process control documentation for power supply facilities that contain operator process control facilities (OPCF). The documentation is to be stored in maintenance areas as hard copies and at the IT portal as scans. The availability of the documentation at power supply facilities increases labor productivity of engineering personnel that perform operational checks and accident recovery activities. Apart from the mandatory set of substation documents (for the operational, maintenance and RPEA personnel), it is suggested to equip substations with OPCF equipment diagrams. This optimization minimizes time expenditures and errors made during maintenance and repair activities on automated supervisory and process equipment at power supply facilities. That enables remote management of systems operation recovery (power supply, resetting of sensors, controllers, data collection and communication devices, etc.). The efficiency of operational checks by engineering personnel is increased. The absence of emergencies ensures uninterrupted power supply to all categories of consumers and thus increases the overall investment potential of the power supply industry. Therefore, the fail-safe operation of equipment is an obvious factor of Russian technology development as well as complies with the Rosseti regulations regarding the common engineering policy in the integrated power grid.

About the Authors

S. V. Vendin
V. Gorin Belgorod State Agricultural University
Russian Federation

Doctor of Engineering, Professor, Head of Chair of Electrical Equipment and Electrical Technology in Agro-Industrial Enterprises, V. Gorin Belgorod State Agricultural University, Belgorod, Russia. 1 Vavilova Str., 308503, p. Maysky, Belgorodsky District, Russia



A. Yu. Mamontov
IDGC of Centre
Russian Federation

Engineer, IDGC of Centre, Belgorodenergo, Belgorod, Russia 42 Preobrazhenskaya Str, 308012, Belgorod, Russia



N. O. Sharshukov
Belgorod Shukhov State Technological University
Russian Federation

Student, Belgorod Shukhov State Technological University, Belgorod, Russia



References

1. PJSC Rosseti regulations on the common power grid engineering policy. Approved by the PJSC Rosseti Board of Directors (Minutes of Meeting no. 138 dated 23.10.2013).

2. Mamontov AYu, Vinogradov AA, Kaplin AV. Kompiuternaya programma raschota parametrov zhivotnovodcheskoy fermy s biostantsiey [Computer program for parameters calculation of an animal farm with biological research station]. Promyshlennaya energetika [Industrial power systems]. 2016; 5: 46 –49. Russian.

3. Mamontov AYu, Vinogradov AA, Nedosekov AYu, Sharshukov NO. Gazovaya turbina i gazoporshnevoy dvigatel v sistemakh elekrosnabzhenia agropromyshlennykh predpriyatiy [Gas turbine and gas reciprocating engine in power supply systems of agro-industrial enterprises]. Energobezopasnost i energosberezhenie [Power safety and saving]. 2016; 2: 31 – 35. Russian.

4. Glinkin EI, Chichiov SI, Kalinin VF. Informatsionno-izmeritelnaya sistema elektrosetevoy kompanii [Information and measurement system of a power grid company]. Moscow: Izdatelsky dom Spektr; 2011.

5. Chichiov SI. Modernizatsia avtomatizirovannoy sistemy kontrolia i ouchota elektoenergii regionalnoy setevoy kompanii [Modernization of automated system for electric power control and metering of a regional grid company]. Energobezopasnost i energosberezhenie [Power safety and saving]. 2010; 2: 20 – 24. Russian.

6. Livshits II. Otsenka zashchishchionnosty obiektov toplivno-energeticheskogo kompleksa [Vulnerability evaluation of fuel and energy facilities]. Energobezopasnost i energosberezhenie [Power safety and saving]. 2015; 5: 5 – 11. Russian.


Review

For citations:


Vendin S.V., Mamontov A.Yu., Sharshukov N.O. Measures to improve the dependability of automated power grid process control equipment. Dependability. 2017;17(1):11-16. https://doi.org/10.21683/1729-2646-2017-17-1-11-16

Views: 8784


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1729-2646 (Print)
ISSN 2500-3909 (Online)